Chair-Air® – Model 9700GR Geriatric Recliner Mattress & Pump System
This unique alternating pressure mattress system allows for patients who are at high risk for pressure sores to be placed in a variety of mobile devices. Patients are no longer confined to bed for the whole day due to risks of sitting without proper pressure redistribution. Chair-Air® systems can be integrated into a geriatric chair, recliner or standard high-back wheelchair. Twenty bladders gently alternate, providing low interface pressures in addition to comfortably supporting the patient. The Chair-Air® 9700GR system includes the 9701 alternating pump. Chair-Air® meets California Technical Bulletin #117 for fire retardancy. An optional fire barrier is available to meet the most stringent fire safety requirements, when requested.
|
![]() |
Chair-Air® Model 9700CAF Alternating Air Wheelchair Cushion and Pump System |
|
| Four individual bladders alternate to provide the patient a superior pressure redistribution seating surface while the unique molded design, with slight abductor pommel, stabilizes the hips and keeps the patient in proper mid-line alignment. The zippered non-skid, stretch-knit cover is anti-microbial and fire-retardant. The Chair-Air® 9700CAF includes the Chair-Air® 9701 alternating pump. | ![]() |
![]() |
|
Chair-Air® AC/DC® Model 9701 Alternating Pump |
||
| The portable Chair-Air AC/DC® Pump allows your patient to be totally mobile. A rechargeable battery backup keeps this system working up to 6 hours per charge, based on the patient’s weight. | ![]() |
For use with Chair-Air®,Geriatric Recliner Mattress &
Chair-Air® Wheelchair Cushion |
|
MODEL 9700GR
|
Chair-Air® – Geriatric Recliner Mattress &Pump System |
|
Dimensions:
|
19″ x 68″ x 2-1/2″-3-1/2″ |
|
Weight:
|
10 lbs. |
|
Air Cells:
|
20 – 3.5″ sacs |
|
Cover:
|
Low shear, zippered multi-stretch Vyvex® III, moisture / vapor permeable top cover, non-skid bottom. Cover is anti-microbial and meets California Technical Bulletin #117 for fire retardancy. |
|
MODEL 9702GR
|
Chair-Air® – Geriatric Recliner Mattress |
|
Dimensions:
|
19″ x 68″ x 2-1/2″-3-1/2″ |
|
Weight:
|
10 lbs. |
|
Air Cells:
|
20 – 3.5″ sacs |
|
Cover:
|
Low shear, zippered multi-stretch Vyvex® III, moisture / vapor permeable top cover, non-skid bottom. Cover is anti-microbial and meets California Technical Bulletin #117 for fire retardancy. |
|
MODEL 9700CAF
|
Chair-Air® – Wheelchair Cushion & Pump System |
|
Dimensions:
|
18″ x 16 ” x 3″ |
|
Weight:
|
3 lbs. |
|
Air Cells:
|
4 – 2.5 ” sacs |
|
Cover:
|
Zippered low shear stretch-knit with non-skid bottom. Cover is anti-microbial and meets California Technical Bulletin #117 for fire retardancy |
|
MODEL 9702
|
Chair-Air® – Wheelchair Cushion |
|
Dimensions:
|
18″ x 16 ” x 3″ |
|
Weight:
|
3 lbs. |
|
Air Cells:
|
4 – 2.5 ” sacs |
|
Cover:
|
Zippered low shear stretch-knit with non-skid bottom. Cover is anti-microbial and meets California Technical Bulletin #117 for fire retardancy |
|
MODEL 9701
|
Chair-Air® – Pump only For use with Geriatric Recliner and Cushion | |
|
Dimensions:
|
14.5″L x 5″W x 12.5″H / 25cm x 25cm x 5.7cm | |
|
Weight:
|
1.6 lbs. / 1.0 kg. (battery and adapter included) | |
|
Power Source :
|
A/C 117V/60hz , D/C 12V amp/hr | |
|
Listings:
|
||
|
Cycle Time:
|
10, 15, 20 Minutes | |
|
Air Flow:
|
4 – 6 liters | |
|
Ground Resistance:
|
0.1 ohms maximum | |
|
WARRANTY
|
||
|
Pumps:
|
1 Year limited | |
|
Mattress:
|
1 year limited | |
|
Cover:
|