Rapid-Air™ Mattress Overlay System- Model 4300
Rapid-Air™ Mattress Overlay Model 4300 Plus – EO277

Alternating Pressure Mattress & Overlay with Low Air Loss

The Rapid-Air™ and Rapid-Air™ alternating Pressure Mattress & Overlay with Gentle Low Air Loss incorporate the features that clinicians demand for their patients in a portable system. The mattress utilizes 18 independent 5.5″ deep air cells to reduce interface pressure for the prevention and treatment of Stages I-IV pressure sore ulcers. User friendly controls and ease of setup make these systems ideal for institutional use and the homebound patient. The mattress is designed to fit all standard hospital beds. Model 4300 & Rapid-Air® Plus Model 4300
Model 4300 & Rapid-Air® Plus Model 4300
Bladders:
Ventilated bladders include 20 lasered air holes in sacral area to help reduce skin maceration by reducing excess moisture under patient. Ventilated bladders assist with the prevention and treatment of pressure ulcers. Air cells are constructed of TPU, thermal polyurethane fabrics. This combination insures strength, durability and patient comfort.The model 4300 Rapid-Air™ features a PPF™ 2.5” pressure redistribution foam base that protects the patient from bottoming out during power outages. The foam is covered in a medical grade nylon which is anti-microbial and fire retardant.

Cover:
Vyvex-I™ nylon cover wicks moisture away from patients skin. The cover is low shear, anti-microbial, fluid resistant, fire retardant and washable. Cover is loose fitting and will conform to the patient. *shown with optional SRS – Side Rail System

CPR Valve quickly deflates mattress system for medical emergencies.

Model 4300 & Rapid-Air® Plus Model 4300 Pump:
Alternating Pressure mode offers the therapeutic benefit of alternating therapy and reactive hyperemia. This helps to reduce interface pressure well below 32mmHg.Control dial adjusts mattress from soft to firm for patient comfort.Normal Pressure Alert indicates that system is
operating correctly.Low Pressure Alert indicates that output needs to be increased for heavier patients or accidental disconnection of hoses.
Model 4300 & Rapid-Air® Plus Model 4300 Optional blower pump is available to quickly inflate and deflate mattress through CPR valve in under 4 minutes
MODEL 4302
Rapid-Air™ – Alternating Pressure Mattress Overlay only
Dimensions:
35″ x 80″ x 5.5″
Weight:
20 lbs.
Air Cells:
18 – 5.5 ” sacs
15 Alternating cells
10 Ventilated cells with 20 lasered air holes
3 Static cells in head section
Mattress Cover:
Vyvex-1™ – Low shear, moisture/vapor permeable. Removable zippered cover,
is anti-microbial and meets California Technical Bulletin #117 for fire-retardancy.
MODEL 4302 Plus
Rapid-Air™ – Alternating Pressure Mattress 
Dimensions:
35″ x 80″ x 8″ (Including foam base)
Weight:
20 lbs.
Air Cells:
18 – 5.5″ sacs
15 Alternating cells
10 Ventilated cells with 20 lasered air holes
3 Static cells in head section
Mattress Cover:
Vyvex-1™ – Low shear, moisture/vapor permeable. Removable zippered cover,
is anti-microbial and meets California Technical
Bulletin #117 for fire-retardancy.
MODEL 4301
Rapid-Air™ – Pump only
Dimensions:
10″L x 5″W x 4.5″H
Weight:
6.2 lbs.
Electrical:
120V 60 hz
Listings:
UL® 544 Medical Equipment
Cycle Time:
10 Minutes
Air Flow:
7.5 Liters per minute
Current Usage:
less than 100 micro amps
Ground Resistance:
0.1 ohms maximum
Power Cord:
12 ft. cord
Construction:
ABS fire retartdant UL 94V-0
WARRANTY
Pumps:
1 Year limited
Mattress:
1 Year limited
Cover:
6 months limited
ORDERING INFORMATION
Model 4300 Plus
Mattress and Pump Control unit 35″ x 80″ x 8″ (including foam base)
Model 4300
Mattress Overlay and Pump Control unit 35″ x 80″ x 5.5″
Model 4300SRS
4300 Mattress System with Safety Rail System for Patient Safety
Model 4300Plus SRS
4300 Plus Mattress System with Safety Rail System for Patient Safety
Model 4300P
Pediatric Mattress 25″ x 45″ x 3.5″
Model 4301
Pump Control Unit
Model 4302
Mattress only
Model 4322
Carry Bag with Strap
Model 9623
Electric Inflator & Deflator
Model 4324
Replacement 5.5″ Ventilated Bladders
Model 4325
Replacement 5.5″ Cell Bladders
Model 4326
Replacement Zippered Cover
Model 4326SRS
Replacement SRS Safety Rail System cover

New Products

Tradewind ATS-RC with Remote ControlAir Pod Lateral Transfer SystemsSrs-ez mattress replacement cover with safety Side rail

ez turn banner

hospital product brochure download

Continuing Education Program

Continuing Education Units

For Clinical or Technical Assistance

 


Medical Professionals & Dealers
CALL 800 795-6115

For technical assistance or help choosing the correct product for your specific application.


virtual inservice avalable

 

Recent Blog

The Difference Between a Lateral Rotation Mattress and an Alternating Pressure Mattress
What are the differences between therapies for the prevention and treatment of Pressure Sore Injuries? Within wound care there are misconceptions between the therapies and when each is appropriate. One of the most common misconceptions is that Lateral Rotation is more advanced than alternating pressure at wound treatment. This is especially true when a patient […]

Read More

Blue Chip introduces Automated mattress functions that directly address a leading cause of skin breakdown.
Sinking into an Alternating Pressure Mattress is a common and overlooked problem that can lead to the development of wounds that must be addressed at the root cause. For those with limited mobility, repositioning is essential to help prevent skin breakdown. A hospital bed frame that allows the patient to change the position of their […]

Read More

Improving Mental Health Care using a Blue Chip Static Air Overlay Mattress
Improving Mental Health Care using a Blue Chip Static Air Overlay Mattress By: Karen Valencia Hamed MSN, AMB-RN, CWOCN, Nurse Care Manager A Mental Health Acute Care inflatable static air overlay mattress Patients in an Acute Mental Health unit have limited options among medical assistive devices. In this environment, limitations are in place to mitigate […]

Read More

Recent Articles