GRZ™ Self Adjusting Air Mattress Replacement System

Convertible Non-Powered Mattress Replacement System

Blue Chip Medical’s innovative GRZ™ self-adjusting air mattress replacement system helps to provide proper pressure redistribution to reduce interface pressures by dynamically adjusting to body weight and movement. The GRZ™ is a non-powered mattress offering pressure redistribution through nine individual dynamic self-adjusting air bladders inside a high resiliency foam shell. The GRZ™ converts to a Powered System via the optional alternating pressure pump. GRZ™’s nine zones redistribute pressure where it is needed most. GRZ™ can be modified into a bariatric mattress that supports patient weights up to 1000 lbs.
Shown with open cover

Top Cover:
Vyvex II™ Low shear nylon butyl backed, fluid proof top cover

Bottom Cover:
Chemsafe™ tri-laminate, fluid-proof,  anti-microbial, fire retardant.

Shown with Optional Gel Flex™ Channel top foam

GRZ mattress cut away
 

Skin Protection Heel Section:
The GRZ™ features a special pressure redistribution heel section constructed of HeelWrap foam. HeelWrap features Sphere “springs” to help protect heels from skin breakdown.
Optional sloped heel section available.

 

 

 

Bladders:
Nine individual dynamic self-adjusting air mattress cells, automatically adjust to the patient’s weight and movement. Urethane/vinyl blend/reforming foam agent, air circulating bladders. Enclosed sleeve for secure positioning.

 

 

non-powered air mattress waterlock infection control system Top Foam:
High-density HR Topper, 2.2 lb., 27 IFD with heel section.
High Resiliency Foam, anti-microbial, fire retardant.Barrier Lok™ Infection Control System
Blue Chip’s exclusive Barrier Lok™ feature virtually seals and protects the inner foam core of the self-adjusting air mattress by preventing the leaching of fluids from penetrating the perimeter seam of the mattress. The Barrier Lok™ ensures that infection control standards are maintained, thereby providing investment protection on all GRZ™ mattress systems.
 

Optional Top Foam:
Gel-Flex™ Channel provides additional
comfort and support for bariatric
patients.

*Note: To order add “GFC” to item number

Optional SRS:
SRS Side Rail Safety System provides
patient safety while meeting entrapment standards
GRZ side rail safety system
GRZ optional pump

Optional Pump:
An alternating air pressure pump converts the system from a non-powered to a powered mattress system.

  • Alternating mode offers the benefit of alternating pressure therapy and reactive hyperemia. This helps to redistribute pressure well below 32mmHg.
  • Static mode for patient care and transfer
  • Static fall-back feature for patient safety
  • Variable Cycle Time 10, 15 & 20 minutes
  • Control dial adjusts the mattress from soft to firm for patient comfort.
  • Normal Pressure Alert indicates that the system is operating correctly.
  • Low-Pressure Alert indicates that output needs to be increased for heavier patients or accidental
    disconnection of hoses.
MODEL 3676
GRZ™ – Self Adjusting Air Mattress only
Dimensions:
36″ x 76″ x 7″
Weight:
48 lbs. packaged
Air Cells:
9 Self-adjusting air cells
Shell:
High resilience foam with Honeycomb SCT® and heel section
Top Cover:
 
Bottom Cover:
Vyvex II™ Nylon Butyl backed, fluid proof, fire retardant top cover, Chemsafe™ tri-laminate. Fluid-proof, anti-microbial, fire retardant.
ORDERING INFORMATION
Model GRZ 3676
Mattress 36” x 76” x 7”   Supports weight to 550
Model GRZ 3680
Mattress 36” x 80” x 7”   Supports weight to 550
Model GRZ 3684
Mattress 36” x 84” x 7”   Supports weight to 550
Model GRZ 4280
Mattress 42” x 80” x 7”   Supports weight to 650
Model GRZ 4880
Mattress 48” x 80” x 7”   Supports weight to 1000
Model GRZ 5480
Mattress 54” x 80” x 7”   Supports weight to 1000
Model GRZ 6080
Mattress 60” x 80” x 7”   Supports weight to 1000
Model GRZ 4610S
Optional Alternating Air Pressure Pump
Model GRZ 3676P
Mattress 36” x 76” x 7”   With Optional Pump Supports weight to 550
Model GRZ 3680P
Mattress 36” x 80” x 7”   With Optional Pump Supports weight to 550
Model GRZ 3684P
Mattress 36” x 84” x 7”   With Optional Pump Supports weight to 550
Model GRZ 4280P
Mattress 42” x 80” x 7”   With Optional Pump Supports weight to 650
Model GRZ 4880P
Mattress 48” x 80” x 7”   With Optional Pump Supports weight to 1000
Model GRZ 5480P
Mattress 54” x 80” x 7”   With Optional Pump Supports weight to 1000
Model GRZ 6080P
Mattress 60” x 80” x 7”   With Optional Pump Supports weight to 1000
Model GRZ SRS
Mattress With Side Rail Safety System
Model GRZ SRSP
Mattress With Optional Pump & Side Rail Safety System
PDAC APPROVED
Medicare Code EO277

New Products

Tradewind ATS-RC with Remote ControlAir Pod Lateral Transfer SystemsSrs-ez mattress replacement cover with safety Side rail

ez turn banner

hospital product brochure download

Continuing Education Program

Continuing Education Units

For Clinical or Technical Assistance

 


Medical Professionals & Dealers
CALL 800 795-6115

For technical assistance or help choosing the correct product for your specific application.


virtual inservice avalable

 

Recent Blog

Blue Chip Medical Products celebrates its 27th year of wound care innovation.
Blue Chip Medical Products proudly commemorates its 27th anniversary as a pioneer in the field of wound prevention and treatment. With a steadfast commitment to excellence and patient care, Blue Chip continually innovates new products that consistently set the standard for clinically effective wound care across the America’s and Europe.  Through relentless research and development […]

Read More

The difference between Alternating Pressure and Air Fluidized Therapy AFT
    COMMON USE ALTERNATING PRESSURE Prevention & Treatment of Stages I-IV Pressure Injury AIR FLUIDIZED THERAPY Treatment of Stages III-IV Pressure Injury, burns, flap surgeries, grafts & unstageable wounds Both AFT and Alternating Pressure therapy are for the treatment of late-stage pressure sores. There are benefits and restrictions to each therapy. However, where, when, […]

Read More

What is Reactive Hyperemia and Why it's Important for Wound Care
Reactive hyperemia is the body’s response to periods of inadequate blood supply to a tissue or organ such as the skin. This phenomenon in wound care, refers to increase of blood circulation in the small arteries and capillaries after the skin has experienced a temporary obstruction in blood flow. Obstruction in blood supply to the […]

Read More

UPCOMING SHOWS

VA-MIAMI – SAFE PATIENT HANDLING & MOBILITY
MIAMI VA MEDICAL CENTER
MARCH 18 TH

MEDTRADE CONFERENCE
DALLAS TX
MARCH 26TH-28TH 2024

VA – SAFE PATIENT HANDLING
SALEM VA MEDICAL CENTER
MAY 16 TH

FIME
FLORIDA INTERNATIONAL MEDICAL EXPO
JUNE 19-21 ST

SER WOCN (WOUND CARE NURSING)
CHATTANOOGA, TN
AUGUST 22 ND – AUGUST 24 TH CHATTANOOGA

Recent Articles