Power Pro™ Elite Integrated Low Air Loss Bed System- Model 9400 EO193

Integrated Bed & Alternating Pressure Mattress System with True Low Air Loss

power pro with integrated pumpThe Power-Pro™ Elite integrated mattress combines two clinically effective therapies: True Low Air Loss and Alternating Pressure. The alternating pressure
mattress utilizes 18 independent 9″ deep air cells to provide proper pressure redistribution for the prevention and treatment of Stages I-IV pressure ulcers. The fully integrated electric bed system features fully electric DC motors, Reverse Trendelenburg, Trendelenburg, High/Low and Cardio position. Bed deck is 7” in low position and 30” in high.
power pro bladders integrated pumpBladders:
Ventilated low air loss cells have air holes throughout the mattress to help
minimize skin maceration by reducing excess moisture under patient. Ventilated bladders assist in the prevention and treatment of pressure ulcers. Air cells are constructed of TPU thermal polyurethane material.
Power Pro integrate bed pumpmdBlower Pump:
The alternating pressure mattress blower pump is controlled by a micro-processor which allows the caregiver total control of comfort and chosen therapy. Cycle time ranges from 5 to 95 minutes. The blower pump inflates the mattress within minutes, reducing the waiting time for therapeutic treatment to begin. Optional pulsating low air loss pump Model 9511-PS allows caregivers to provide pulsating low air loss therapy.
MODEL 9500
Power-Pro™ Elite  – Mattress and Pump
Dimensions:
36″ x 80″ x 9″
Weight:
23 lbs.
Air Cells:
18 – 9 ” deep cells
Ventilated bladders with air holes throughout mattress
Mattress Cover:
Vyvex-III™ – Urethane coated, multi-stretch, low shear, moisture resistant / vapor permeable quilted cover. Removable, zippered cover, is anti-microbial and meets California Technical Bulletin #117 for fire-retardancy.
MODEL 9501
Power-Pro™ Elite  – Pump only
Dimensions:
17″L x 7″W x 10.5″H
Weight:
12 lbs.
Electrical:
120V 60 hz
Listings:
UL® 544 Medical Equipment
Cycle Time:
5 – 95 Minutes
Air Flow:
1800 Liters per minute
Current:
5A
Ground Resistance:
0.1 ohms maximum
Power Cord:
12 ft. cord with hospital grade plug
WARRANTY
Mattress & Pump:
1 Year limited
Frame:
1 year limited
Cover:
6 months limited
ORDERING INFORMATION
Model 9400
Power Pro™ Elite Integrated Low Air Loss Bed System
Model 9511
Power Pro™ Elite Blower pump only
Model 9526-SRS
Power Pro™ replacement SRS side rail safety system


New Products

Tradewind ATS-RC with Remote ControlAir Pod Lateral Transfer SystemsSrs-ez mattress replacement cover with safety Side rail

ez turn banner

hospital product brochure download

Continuing Education Program

Continuing Education Units

For Clinical or Technical Assistance

 


Medical Professionals & Dealers
CALL 800 795-6115

For technical assistance or help choosing the correct product for your specific application.


virtual inservice avalable

 

Recent Blog

What is Reactive Hyperemia and Why it's Important for Wound Care
Reactive hyperemia is the body’s response to periods of inadequate blood supply to a tissue or organ such as the skin. This phenomenon in wound care, refers to increase of blood circulation in the small arteries and capillaries after the skin has experienced a temporary obstruction in blood flow. Obstruction in blood supply to the […]

Read More

The Difference Between a Lateral Rotation Mattress and an Alternating Pressure Mattress
What are the differences between therapies for the prevention and treatment of Pressure Sore Injuries? Within wound care there are misconceptions between the therapies and when each is appropriate. One of the most common misconceptions is that Lateral Rotation is more advanced than alternating pressure at wound treatment. This is especially true when a patient […]

Read More

Blue Chip introduces Automated mattress functions that directly address a leading cause of skin breakdown.
Sinking into an Alternating Pressure Mattress is a common and overlooked problem that can lead to the development of wounds that must be addressed at the root cause. For those with limited mobility, repositioning is essential to help prevent skin breakdown. A hospital bed frame that allows the patient to change the position of their […]

Read More

Recent Articles